COMPULINK EMR Integration with CBOX
|
Supported Devices
|
AKR550
|
AKR750
|
ALM500
|
ALM700
|
APH550
|
WAM-700+
|
Vision-R 800
|
Vision-R 700
|
|
Office’s Computer Configuration Setup
Compulink will set up a shared drive.
The drive will be called \\eyeserver or it will have Compulink or EYECARE in the title. It will be located on the O:\Drive (or any other driver that could be used and or mapped) in this case the F:\Drive is being used.
Locate the F:\ Drive and Open
Essilor folder
Eyecare folder
Interface folder
ACBSInter.ini file (There may be more than one CBSInter.ini files) (Ex. CCBSInter.ini, BCBSInter.ini etc.) Each file will need to be modified as shown in steps 6, 7, 8, below.
ImportFileDirectory and ImageImportFileDirectory both need to be changed to the share folder location of the VR-800.
The location of the VR-800 will be \\tsclient\R\
Once file has been modified go to File, then Save
Once file is done it should look like the file below.
VisionR 800 File Setup
Login with User Name and Password
Select Patient
In the Lower Right Hand Corner, Click on Utility Icon
Then click on WorkStation Configuration
Click on Edit
Click on Instruments tab
Add manually the Instrument, Port, Usage, WAN
Click Save
Click Search
Type in Last, First Name, then Search
Double Click on Patient
Click on Exam
Click on Add
Double click Complete Exam (HiRes)
Select Then Add the Unique Identifier
Select Search
Check Mark the Selected All File:
Click Import
Select Add Unique Identifier with Patients name
Click Search
Check Import All Data
Click Import
Go to WorkUp Tab, should look like this:
Related Articles
VisionR 800 Integration with Compulink
Office’s Computer Configuration Setup Compulink will set up a shared drive. The drive will be called \\eyeserver or it will have Compulink or EYECARE in the title. It will be located on the O:\Drive (or any other drive could be used and or mapped) in ...
Integration with Revolution EHR - VisionR 800
IMPORTANT NOTE: This User Manual is designed to provide practices all fundamental information required to perform the setup without assistance. However, if assistance is needed, we request that a call be scheduled with Customer Support. Due to the ...
Revolution EHR Integration with CBOX
IMPORTANT NOTE: This User Manual is designed to provide practices all fundamental information required to perform the setup without assistance. However, if assistance is needed, we request that a call be scheduled with Customer Support. Due to the ...
Devices compatible with CBOX
The cbox device can be ordered using the PN CBOX331 Essilor Equipment Settings Materials AKR300 9600/8/N/1 PN C84R55 AKR550 9600/8/N/1 PN C84R55 AKR750 9600/8/N/1 PN C84R55 APH550 9600/8/N/1 PN C84R55 ALM500 9600/8/N/1 PN C84R55 ALM700 9600/8/N/1 ...
Integration with Uprise - VisionR 800
In Screening Room Uprise welcome page : Add a new patient or Search for patient if (s)he exists. Enter patient data and click on EHR on the left : Uprise will give an ID to your patient beginning by PTXXXX. Click on Comprehensive Exam This window ...